flag_vietnam
logo-solutech
Hot News
tai-sao-nen-khu-trung-bang-clo2
Did you know: Why should chlorine disinfectant (Chlorine) be replaced with Chlorine Dioxide (ClO2)?
lam-mem-nuoc-ho-boi
Groundwater, other ingredients, calcium and manganese salts. Both substances cause total hardness. Just changing the pH value or temperature can cause precipitation. These visible precipitates (lime) precipitate on pipes, tank walls, chillers, fountains and steam generators. These precipitates can cause mechanical and thermal costs. Therefore, if you do not want to, it will cause unnecessary equipment failures!
quy-trinh-tu-dong
Optimizing and automating a line, such as reducing chemical consumption, treating wastewater in accordance with standards, quantifying and controlling the quantitative process correctly ... is always a problem. Urgency needs to be dealt with. If the customer is looking for a solution to this problem or wants systems with values and benefits that are far greater than the metering pumps, sensors, controllers or other individual devices, the main ProMinent is the right choice.

Technology of measurement, control and sensor

In our opinion, the use of measurement and control technology in liquid dosing can be called "intelligent dosing". Because the measurement and control technology, if used appropriately, will bring the optimal effect for chemical quantification.
dinh-luong-thong-minh-cong-nghe-do-luong-dieu-khien-cam-bien
The use of appropriate measurement and control technology in chemical dosing offers the following advantages:

Increase safety
Increase processing efficiency (increase product quality ...)
Reduce chemical costs quantitatively
Reduce the cost of quantitative chemical residue treatment
Clear measurement data, updated in real time
Our product range in measurement and control technology includes a wide range of products, designed ideally for serving our customers' quantitative requirements.

Sensor

ProMinent® series of sensor products enable precise determination of the concentration of parameters.

We provide sensors for the following parameters:

PH
Redox
Chlorine
Conductivity
Chlorine dioxide
Chlorite
Bromine
Ozone
Hydrogen peroxide
Peracetic acid
Fluoride
Dissolved oxygen concentration
Temperature
With a variety of adjustment options, our product range can be customized and easily integrated into customers' systems. Can be installed in:

In joints to avoid main flow
In the tubes of the tanks or channels
Directly in tube
Besides, we also provide all kinds of components, accessories such as:

In-line probe housing
Dip pipe
Changeover fitting
Adaptor
Instrumentation and control

We provide metering and control equipment that is tailored to customer requirements and classified into different power levels based on certain requirements. This process begins by transmitting the measuring signals to the PLC, then passing through the calibration device with the values ​​of the measurement value. These calibration devices, including controllers, have been designed to fulfill simple to complex control requirements. Integrating a control cycle into a bus system can be done via our PROFIBUS®-DP and CANopen-Bus units.

Device Drivers

1 channel: D1C
2 channels: D2C
Multi-channel: Dulcomarin II
Measuring device

Operatable, with display: DMT
PH measuring device: PH V1
T-transducer: Pt 100 V1
Redox measurement device: RH V1
Besides individual devices and parts, we also provide complete solutions for measuring certain parameters. Customers have complete peace of mind when using ProMinent's products; Because we always offer a wide range of products, suitable for many other processes and parts, including the technologies used many years ago.
Theo ProMinent
Date Posted: 29/12/2018 10:29:00
APPLICATION
«   12  »

CUSTOMERS WE SERVE

nestle
lavie
heineken
1biasaigon
carlsberg
3abinbev
8nutifood
tanhiepphat
9vnm-new
bel
thmilk
17nsrp
nuiphaomining
schaeffler-logo
6dnphawaco
duongnhat
7pepsi
coca-cola
Hotline
Hotline