Groundwater, other ingredients, calcium and manganese salts. Both substances cause total hardness. Just changing the pH value or temperature can cause precipitation. These visible precipitates (lime) precipitate on pipes, tank walls, chillers, fountains and steam generators. These precipitates can cause mechanical and thermal costs. Therefore, if you do not want to, it will cause unnecessary equipment failures!
quy-trinh-tu-dong
Optimizing and automating a line, such as reducing chemical consumption, treating wastewater in accordance with standards, quantifying and controlling the quantitative process correctly ... is always a problem. Urgency needs to be dealt with. If the customer is looking for a solution to this problem or wants systems with values and benefits that are far greater than the metering pumps, sensors, controllers or other individual devices, the main ProMinent is the right choice.

UV Systems

UV radiation is a safe, chemical-free and reliable method of disinfection in modern water treatment. ProMinent Dulcodes® UV systems exploit the safety and reliability of UV disinfection in a wide range of applications. Scientific research and the many systems successfully in operation prove that UV is ideally suited to water disinfection.
he-thong-uv-prominent
Gentle on people and the environment

UV radiation is a safe, chemical-free and reliable method of disinfection in modern water treatment. ProMinent Dulcodes® UV systems exploit the safety and reliability of UV disinfection in a wide range of applications. Scientific research and the many systems successfully in operation prove that UV is ideally suited to water disinfection.

Our hero: UV-C radiation

No one wants germs - and UV-C radiation in particular, with a wavelength ranging from 240 to 280 nm, attacks the vital DNA of the bacteria directly. The bacteria lose their reproduction capability and are destroyed. Even parasites, like Cryptosporidia or Giardia, which are extremely resistant to chemical disinfectants, are efficiently reduced.

Not just for potable water

Photochemical reactions triggered by UV are used in other ProMinent applications too. The undesirable presence of combined chlorine in swimming pool water is reduced by UV radiation, achieving significant savings in fresh water. Oxidants, such as ozone, chlorine or chlorine dioxide, are reliably reduced in the production water used in the food and pharmaceutical industries, eliminating the need for expensive active carbon filters.

The advantages of UV treatment

Immediate and safe disinfection without the addition of chemicals. This results in highly effective disinfection regardless of the pH value. No undesirable substances are formed. The odour and taste of the water are not impaired. There is no need to store and handle chemicals. No reaction vessel or reaction tanks are required. A ProMinent UV system takes up very little space and keeps investment and operating costs low while delivering exceptional reliability and performance.

Our best: the Dulcodes UV disinfection systems
  • Uniform radiation of the entire water flow thanks to optimised system hydraulics with flow-optimised inlet zone
  • Use of UV lamps with a long lamp lifetime and high UV-C output
  • Automatic cleaning system
  • System controller with comprehensive monitoring and reporting functions
  • Display of all important operating parameters and reporting of faults in plain text
  • Trend display of the variation of the UV sensor signal over time
  • Analogue output sensor signal and fault indicating relay
  • Use of modern electronic ballasts with bus technology for lamp-friendly ignition and operation
  • Individual lamp monitoring
  • Direct control of automatic shut-off and flushing valves.
https://www.prominent.com/en/Products/Products/Disinfection-Systems-and-Oxidation-Systems/UV-Systems/pg-uv-systems.html
Date Posted: 29/12/2018 10:01:00
APPLICATION
«    12   »

CUSTOMERS WE SERVE

nestle
lavie
heineken
1biasaigon
carlsberg
3abinbev
8nutifood
tanhiepphat
9vnm-new
bel
thmilk
17nsrp
nuiphaomining
schaeffler-logo
6dnphawaco
duongnhat
7pepsi
coca-cola
Hotline
Hotline