Groundwater, other ingredients, calcium and manganese salts. Both substances cause total hardness. Just changing the pH value or temperature can cause precipitation. These visible precipitates (lime) precipitate on pipes, tank walls, chillers, fountains and steam generators. These precipitates can cause mechanical and thermal costs. Therefore, if you do not want to, it will cause unnecessary equipment failures!
quy-trinh-tu-dong
Optimizing and automating a line, such as reducing chemical consumption, treating wastewater in accordance with standards, quantifying and controlling the quantitative process correctly ... is always a problem. Urgency needs to be dealt with. If the customer is looking for a solution to this problem or wants systems with values and benefits that are far greater than the metering pumps, sensors, controllers or other individual devices, the main ProMinent is the right choice.

What is diaphragm pressure gauge and how it works?

Diaphragm pressure gauge is a necessary accessory in water treatment, industrial production, chemical industries, etc. To effectively use pressure gauges in liquid dosing applications, it is necessary to understand specify some requirements and operating conditions of the equipment.
prominent-pump-dosing-system-solutech
Diaphragm pressure gauges (or pressure gauges) are used to measure the pressure of chemicals. The application of diaphragm pressure gauge as fllowing information:

Requirements:
+ Accurate representation of chemical pressure
+ Chemicals are highly corrosive, may contain dirt

Operating conditions:
+ The pressure of the chemical changes
+ The meter is installed at the suction or discharge end of the pump

Structure of diaphragm pressure gauge:


Connect to pipes with common standards such as BPT, ASTM, JIS, easy to install.

Usage and amissible error:
• Amissible error 0.3%
• Error will increase with temperature change, every 10°C will increase ±0.4%
• The temperature limit must match the operating temperature of the fluid
• The maximum pressure of the fluid must not exceed the maximum allowable pressure of the meter
• If the pressure is high, it will cause tearing of the membrane or the force transmission fluid will leak out
• Replenish fluid if it leaks out.

More: ProMinent Diaphragm Pressure Gauge Guard MDM 902

Admin TH
Date Posted: 21/02/2020 18:02:00
APPLICATION
«   12  »

CUSTOMERS WE SERVE

nestle
lavie
heineken
1biasaigon
carlsberg
3abinbev
8nutifood
tanhiepphat
9vnm-new
bel
thmilk
17nsrp
nuiphaomining
schaeffler-logo
6dnphawaco
duongnhat
7pepsi
coca-cola
Hotline
Hotline